Abstract

We report the first experiments showing the reversibility of transient acoustic waves through high-order multiple scattering by means of an acoustic time-reversal mirror. A point source generates a pulse which scatters through 2000 steel rods immersed in water. The time-reversed waves are found to converge to their source and recover their original wave form, despite the high order of multiple scattering involved and the usual sensitivity to initial conditions of time-reversal processes. Surprisingly, the observed resolution was one-sixth of the theoretical limit for the mirror's aperture.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.