Abstract

Our aim was to show that bladder cuff excision and distal ureterectomy can be safely performed by using the LigaSure device during robotic-assisted laparoscopic nephroureterectomy. A 60-year-old man presented with gross hematuria. He was diagnosed with upper urinary tract transitional cell carcinoma (TCC) on the left side and was scheduled for robot-assisted laparoscopic surgery. Without changing the patient's position, sealing with the LigaSure atlas for bladder cuff excision and distal ureterectomy was performed. The operating time was 140 minutes from the initial incision to skin closure of all incisions. The estimated blood loss during the surgery was 120 mL. There were no intraoperative or postoperative complications. The Foley drain was removed on day 3 after normal cystographic findings, and the patient was discharged from the hospital on the fourth postoperative day. Robot-assisted nephroureterectomy with distal ureterectomy in the same position using a LigaSure device is a safe alternative for upper tract transitional cell carcinoma.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.