Abstract

ObjectiveTo evaluate the intraoperative and short-term postoperative outcomes of a novel robotic intracorporeal π-shaped esophagojejunostomy (EJS) after D2 total gastrectomy (TG) using the Da Vinci robotic surgical system for intracorporeal anastomosis after TG.BackgroundIntracorporeal π-shaped EJS, using a linear stapler, was recently reported for laparoscopic total gastrectomy in patients with gastric cancer. However, robotic intracorporeal π-shaped EJS using a linear stapler has not been reported. This report aimed to describe the use of a novel technique for π-shaped EJS using the Da Vinci robotic system.MethodsRobotic intracorporeal π-shaped esophagojejunostomy after total gastrectomy was performed in 11 consecutive patients diagnosed with early gastric cancer, and their perioperative outcomes were analyzed.ResultsAll the operations were successful without conversion to open or laparoscopic surgery and postoperative complications. The total number of patients was 11 (7 males and 4 females). The mean age of the patients was 63.36 ± 10.56 years old. Seven patients were diagnosed with cardia cancer, 3 patients were diagnosed with gastric body cancer, and 1 patient was diagnosed with gastric antrum cancer. The patients’ mean proximal resection margin was 3.18 ± 1.17 cm, the distal resection margin was 6.18 ± 1.40 cm, the mean length of the incision was 4.55 ± 0.69 cm, the mean operative time was 287.27 ± 30.69 min, the mean day of first flatus was 3.27 ± 0.79 days, the mean day of the start of diet was 2.91 ± 0.94 days, the mean postoperative hospital stay was 11.45 ± 5.13 days, and the mean operative blood loss was 47.27 ± 31.33 ml. No complications were observed during anastomosis, and the median anastomosis time was 19.5 min. The mean number of lymph node dissections was 17.91 ± 4.59, the mean number of positive lymph nodes was 0.45 ± 0.69, all patients were diagnosed with stage I–II gastric cancer, and the mean maximum diameter of the tumor was 2.67 ± 1.30 cm. All the patients had a smooth hospital discharge.ConclusionA novel robotic gastrectomy with intracorporeal π-shaped EJS for esophagojejunal anastomosis described and shows acceptable resulted. This technique has the potential to offer better short-term surgical outcomes and overcomes the drawbacks of laparoscopy with a decreased risk of complications during and after surgery.

Highlights

  • Gastric cancer is the third most common cause of mortality and is the fourth most commonly diagnosed cancer [1]

  • Robotic intracorporeal π-shaped esophagojejunostomy after total gastrectomy was performed in 11 consecutive patients diagnosed with early gastric cancer, and their perioperative outcomes were analyzed

  • No complications were observed during anastomosis, and the median anastomosis time was 19.5 min

Read more

Summary

Introduction

Gastric cancer is the third most common cause of mortality and is the fourth most commonly diagnosed cancer [1]. The procedure became more popular, and it is one of the standard procedures (minimally invasive) for the treatment of early gastric cancer (EGC). In Korea, from 2004 to 2009, the number of laparoscopic surgeries for gastric cancer increased from 740 to 3783 [5]. Due to advances in surgical instruments, surgical experience and a lot of clinical evidence regarding laparoscopic gastrectomy, which was collected over last two decades, especially from Korea and Japan, some experts have extended the use of minimally invasive laparoscopic gastrectomy for gastric cancer from early gastric cancer (EGC) to advanced gastric cancer (AGC), because it is associated with a short hospital stay, earlier bowl moment return, a short bed stay, a decreased inflammatory response, less postoperative pain, and equivalent oncological aspects compared to open surgery [6]. Intracorporeal π-shaped EJS, using a linear stapler, was recently reported for laparoscopic total gastrectomy in patients with gastric cancer. Robotic intracorporeal π-shaped EJS using a linear stapler has not been reported. This report aimed to describe the use of a novel technique for π-shaped EJS using the Da Vinci robotic system

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call