Abstract

We performed a retrospective review in a matched group of patients on the use of robotic-assisted UKA implantation versus UKA performed using standard operative techniques to assess differences between procedures. While both techniques resulted in reproducible and excellent outcomes with low complication rates, the results demonstrate little to no clinical or radiographic difference in outcomes between cohorts. Average operative time differed significantly with, and average of 20minutes greater in, the robotic-assisted UKA group (P=0.010). Our minimal clinical and radiographic differences lend to the argument that it is difficult to justify the routine use of expensive robotic techniques for standard medial UKA surgery, especially in a well-trained, high-volume surgeon. Further surgical, clinical and economical study of this technology is necessary.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.