Abstract

BackgroundThe use of unicompartmental knee arthroplasty (UKA) has increased and new technologies have been developed to improve patient survival and satisfaction, soft tissue balance, alignment, and component size. Robot-assisted systems offer an increase in surgical precision and accuracy. The purpose of this study is to evaluate the precision of component position using five radiological parameters in conventional and robotic-assisted medial UKA using the NAVIO system.MethodsA cohort study was designed for patients who underwent medial UKA between April 2017 and March 2019 in a single center. Patients were allocated in the conventional (UKA-C) or robotic-assisted (UKA-R) group. The variables analyzed were age, gender, affected knee side, length of hospital stay, surgical time, and radiological measurements such as anatomical medial distal femoral angle (aMDFA), anatomical medial proximal tibial angle (aMPTA), tibial slope, the sagittal femoral angle, and the component size. A target was defined for each measurement, and a successful UKA was defined if at least four radiological measures were on target after surgery. Also, patients’ reported outcomes were evaluated using the Oxford Knee Score (OKS) and a numeric rating scale (NRS) for pain.ResultsThirty-four patients were included, 18 of them underwent UKA-R. The success rate for UKA in the UKA-R group was 87%; meanwhile, in the UKA-C group this was 28%, this difference was significant and powered (Fisher’s exact test, p = 0.001; 1 − β = 0.95). Also, a 5-point difference in favor of the UKA-R group in the median OKS (p = 0.01), and a significantly lower median NRS for pain (p < 0.000) were found after surgery.ConclusionsUKA-R achieved more precision in the radiological parameters’ measure in this study. Also, UKA-R has a trend towards a better OKS and a lower NRS for pain at short-term follow-up.

Highlights

  • The use of unicompartmental knee arthroplasty (UKA) has increased and new technologies have been developed to improve patient survival and satisfaction, soft tissue balance, alignment, and component size

  • Patients undergoing UKA had a lower rate of complications, faster functional recovery, and better satisfaction compared to total knee arthroplasty (TKA) [15,16,17,18]

  • This study aims to evaluate the precision of component position using five radiological parameters in conventional and robotic-assisted medial UKA using the NAVIO system

Read more

Summary

Introduction

The use of unicompartmental knee arthroplasty (UKA) has increased and new technologies have been developed to improve patient survival and satisfaction, soft tissue balance, alignment, and component size. The purpose of this study is to evaluate the precision of component position using five radiological parameters in conventional and robotic-assisted medial UKA using the NAVIO system. Patients undergoing UKA had a lower rate of complications, faster functional recovery, and better satisfaction compared to total knee arthroplasty (TKA) [15,16,17,18]. Robotic assistance may play an essential role in decreasing the rate of malposition of the components in UKA [19, 20], theoretically leading to better clinical results and longer survival rates [21,22,23,24,25,26,27]

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call