Abstract
Standard in-vitro spine testing methods have focused on application of isolated and/or constant load components while the in-vivo spine is subject to multiple components that can be resolved into resultant dynamic load vectors. To advance towards more in-vivo like simulations the objective of the current study was to develop a methodology to apply robotically-controlled, non-zero, real-time dynamic resultant forces during flexion–extension on human lumbar motion segment units (MSU) with initial application towards simulation of an ideal follower load (FL) force vector.A proportional-integral-derivative (PID) controller with custom algorithms coordinated the motion of a Cartesian serial manipulator comprised of six axes each capable of position- or load-control. Six lumbar MSUs (L4–L5) were tested with continuously increasing sagittal plane bending to 8Nm while force components were dynamically programmed to deliver a resultant 400N FL that remained normal to the moving midline of the intervertebral disc. Mean absolute load-control tracking errors between commanded and experimental loads were computed. Global spinal ranges of motion and sagittal plane inter-body translations were compared to previously published values for non-robotic applications.Mean TEs for zero-commanded force and moment axes were 0.7±0.4N and 0.03±0.02Nm, respectively. For non-zero force axes mean TEs were 0.8±0.8N, 1.3±1.6Nm, and 1.3±1.6N for Fx, Fz, and the resolved ideal follower load vector FLR, respectively. Mean extension and flexion ranges of motion were 2.6°±1.2° and 5.0°±1.7°, respectively. Relative vertebral body translations and rotations were very comparable to data collected with non-robotic systems in the literature.The robotically coordinated Cartesian load controlled testing system demonstrated robust real-time load-control that permitted application of a real-time dynamic non-zero load vector during flexion–extension. For single MSU investigations the methodology has potential to overcome conventional follower load limitations, most notably via application outside the sagittal plane. This methodology holds promise for future work aimed at reducing the gap between current in-vitro testing and in-vivo circumstances.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.