Abstract

AimHere, we describe a step‐by‐step standardized technique for tailgut cyst resection using a single‐docking robotic approach.MethodEach step of the technique is illustrated using a composite collection of four operative patient videos to demonstrate the advantages and feasibility of this technique. The robot platform utilised is Da Vinci Xi.ResultsFive female patients have undergone this operation in our unit. The size of tumours ranged from 12 to 45 mm. Median operating time was 100 min (range 90–150). Mean blood loss in all the patients was less than 50 ml. There were no major intraoperative complications. One patient had a postoperative presacral collection which required radiological drainage. Length of stay in all patients was one day.ConclusionsThis technique using a single‐docking robotic approach appears safe and feasible. The robotic approach results in improved dexterity and more accurate dissection, better retraction and excellent vision which improves the ease of operating in the pelvis. Therefore, this approach can be replicated for use in a wide variety of patients with tailgut cysts.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call