Abstract
The objective of this study was to evaluate the safety and feasibility of 99mTc-based prostate-specific membrane antigen (PSMA) robot-assisted-radioguided surgery to aid or improve the intraoperative detection of lymph node metastases during primary robot-assisted radical prostatectomy (RARP) for prostate cancer (PCa). Methods: Men with primary high-risk PCa (≥ cT3a, International Society of Urological Pathology (ISUP) grade group ≥ 3 or prostate-specific antigen of ≥ 15 ng/mL) with potential lymph node metastasis (Briganti nomogram risk > 10% or on preoperative imaging) were enrolled in the study. Patients underwent staging 68Ga-PSMA PET/CT scanning. Preoperatively, a 99mTc-labeled PSMA ligand (99mTc PSMA I&S; 500 MBq) was administered followed by SPECT/CT. A RARP including extended pelvic lymph node dissection was performed, with intraoperative tracing of PSMA-avid tissues using a prototype DROP-IN γ-probe. Resected specimens were also measured ex vivo. Histopathologic concordance with probe findings was evaluated. A radiotracer count of ≥ 1.5 times the background reference (invivo), and ≥ 10 (absolute count) in the ex vivo setting, was considered positive. Results: Twelve patients were included (median age, 68 y, and prostate-specific antigen, 9.15 ng/mL). Most of the patients harbored ISUP 5 PCa (75%) and had avid lymph nodes on preoperative PSMA PET (64%). The DROP-IN probe aided resection of PSMA-avid (out-of-template) lymph nodes and residual disease at the prostate bed. Eleven metastatic lymph nodes were identified by the probe that were not observed on preoperative 68Ga-PSMA PET/CT. Of the 74 extraprostatic tissue specimens that were resected, 22 (29.7%) contained PCa. The sensitivity, specificity, positive predictive value, and negative predictive value of inpatient use of the γ-probe were 76% (95% CI, 53%-92%), 69% (95% CI, 55%-81%), 50%, and 88%, respectively. Ex vivo, the diagnostic accuracy was superior: 76% (95% CI, 53%-92%), 96% (95% CI, 87%-99%), 89%, and 91%, respectively, for sensitivity, specificity, positive predictive value, and negative predictive value. Of the missed lymph nodes invivo (n = 5) and ex vivo (n = 5), 90% were micrometastasis (≤3 mm). No complications greater than Clavien-Dindo Grade I occurred. Conclusion: Robot-assisted 99mTc-based PSMA-radioguided surgery is feasible and safe in the primary setting, optimizing the detection of nodal metastases at the time of RARP and extended pelvic lymph node dissection. Further improvement of the detector technology may optimize the capabilities of robot-assisted 99mTc-based PSMA-radioguided surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.