Abstract
The coupling of the energy stability and spatial uniformity of the laser beam before and after second harmonic generation (SHG) was analyzed. SHG experiments were performed using a Nd:YAG nanosecond laser and LBO crystals, and images, pulse shapes, and energies were measured. The relationship between energy stability and spatial uniformity uses a formula derived from the previous study to analyze changes in energy stability and spatial uniformity of the input beam and converted beam. In addition, the measured input beam shape and energy are compared with the results of applying the SHG converting equation considering pump depletion. Both methods were similar to the experimental results when corrected by empirical factors. Through SHG, it was confirmed that there is an optimal point of energy stability and spatial uniformity of the laser beam near the critical power.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.