Abstract
Simple SummaryRobotic radiosurgery (RRS) allows for the accurate treatment of primary tumors or metastases with high single doses. However, organ motion during or between fractions can lead to imprecise irradiation. We sought to evaluate the risks and advantages of fiducial marker (FM) implantation regarding clinical complications, marker migration, and motion amplitude. Complications were most common in Synchrony®-tracked lesions affected by respiratory motion, particularly lung lesions. Pneumothoraces and pulmonary bleeding were the most common complications. An increased complication rate was associated with concomitant biopsy sampling and FM implantation. Most FM migration observed in this study occurred after CT-guided placements and clinical FM insertions. The largest motion amplitudes were observed in hepatic and lower lung lobe lesions. This study highlights the benefits of marker implantation, especially in lesions with a large motion amplitude, including hepatic lesions and lesions of the lower lobe of the lung located >100.0 mm from the spine.Fiducial markers (FM) inserted into tumors increase the precision of irradiation during robotic radiosurgery (RRS). This retrospective study evaluated the clinical complications, marker migration, and motion amplitude of FM implantations by analyzing 288 cancer patients (58% men; 63.1 ± 13.0 years) who underwent 357 FM implantations prior to RRS with CyberKnife, between 2011 and 2019. Complications were classified according to the Society of Interventional Radiology (SIR) guidelines. The radial motion amplitude was calculated for tumors that moved with respiration. A total of 725 gold FM was inserted. SIR-rated complications occurred in 17.9% of all procedures. Most complications (32.0%, 62/194 implantations) were observed in Synchrony®-tracked lesions affected by respiratory motion, particularly in pulmonary lesions (46.9% 52/111 implantations). Concurrent biopsy sampling was associated with a higher complication rate (p = 0.001). FM migration occurred in 3.6% after CT-guided and clinical FM implantations. The largest motion amplitudes were observed in hepatic (20.5 ± 11.0 mm) and lower lung lobe (15.4 ± 10.5 mm) lesions. This study increases the awareness of the risks of FM placement, especially in thoracic lesions affected by respiratory motion. Considering the maximum motion amplitude, FM placement remains essential in hepatic and lower lung lobe lesions located >100.0 mm from the spine.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.