Abstract

To examine the risk of glove tears associated with arthroscopic knot tying using 4 commonly used high-tensile strength sutures and 2 different types of gloves. We analyzed 2 different surgical latex glove types (0.24-mm-thick powder-free and 0.32-mm-thick powdered) for perforation after arthroscopic knot tying with 4 different high-tensile strength sutures: Hi-Fi (ConMed Linvatec, Largo, FL), Ultrabraid (Smith & Nephew, Memphis, TN), FiberWire (Arthrex, Naples, FL), and Orthocord (DePuy Mitek, Raynham, MA). All knots were tied by a double-gloved single surgeon. Twelve trials of 4 knots each were performed for every glove-suture combination. All gloves were analyzed for perforation by a blinded evaluator using visual inspection, hydro-insufflation, and electroconductivity. The overall incidence of glove perforation was 3.4% and was detectable only by the electroconductivity method; the other 2 methods did not detect any perforations. There was a statistically significantly higher rate (P < .001) of perforations in the 0.32-mm powdered gloves (6.8%) compared with the 0.24-mm powder-free gloves (0%). Perforation of the inner glove occurred 5.7 times more frequently than perforation of the outer glove. However, simultaneous perforation of both the inner and outer gloves did not occur in any set. The Hi-Fi suture was involved in 6 perforations compared with 4 for FiberWire, 3 for Ultrabraid, and 0 for Orthocord. Double gloving provides an adequate surgical barrier between the surgeon and the patient during arthroscopic knot tying with high-tensile strength sutures as indicated by the low incidence of glove perforations in our study in an in vitro biomechanical evaluation. There were no instances of simultaneous perforation of both the inner and outer gloves. All perforations occurred only in the thicker (0.32-mm) powdered gloves. Glove tears and finger lacerations have been reported with the use of high-tensile strength sutures during arthroscopic shoulder surgery, thereby raising a concern for safety and disease transmission. This study addresses these concerns by evaluating the risk of glove tears during arthroscopic knot tying.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.