Abstract

116 Background: To determine the dosimetric characteristics and risk of breast fibrosis using a normal tissue complication probability (NTCP) model in conjunction with a novel preoperative stereotactic radiotherapy system called the GammaPod. Results are compared with linac based post-lumpectomy APBI plans for the same cohort. Methods: The GammaPod breast SBRT system consists of a Co-60 irradiation unit in combination with an immobilization device with embedded fiducials. Eight patients were enrolled in an IRB-approved protocol and underwent CT scans in the prone position with breast immobilization. A preoperative target (GTV) was synthesized to match the tumor location and volume reported in imaging studies obtained prior to surgery (0.3-2.4 cc). The GTV was expanded by 1.5 cm to create a CTV, and a PTV was created using an additional 0.3 cm margin. The PTV was prescribed 25.5 Gy in 3 fx, which is radiobiologically equivalent to conventional APBI doses of 38.5 Gy in 10 fx. Following the radioablative experience in NSCLC, we also planned to deliver 60.0 Gy to the GTV+0.3 cm as a simultaneous boost in conjunction with the 25.5 Gy PTV prescription dose. For comparison, linac-based treatment plans were created for the same cohort following NSABP B-39 guidelines. Whole breast dosimetry was analyzed in terms of biologically equivalent dose (BED) and Lyman NTCP analysis was performed. Results: The volume of ipsilateral breast receiving 10, 20, 50, and 100% of the prescribed dose was substantially smaller in GammaPod vs. APBI plans, with cohort averages of 19.3, 13.0, 7.1 and 4.0% vs. 75.8, 67.3, 48.1 and 27.6% respectively (p<0.001). Even though the PTV equivalent uniform BED (EUD) was substantially higher in GammaPod plans (87.9 Gy vs. 57.3 Gy), the ipsilateral breast EUD was still smaller in these plans, 18.9 ± 5.0 Gy vs. 47.2 ± 3.2 Gy (p<0.001). Corresponding NTCP predictions for breast fibrosis rates following GammaPod and APBI treatments were 0.2 ± 0.1% vs. 2.8 ± 0.8% (p<0.001), respectively. Conclusions: The GammaPod system improves upon traditional post-lumpectomy linac-based APBI by decreasing dose to the ipsilateral breast as well as the predicted rates of breast fibrosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.