Abstract

The purpose of this study was to evaluate patient, operative, implant, surgeon, and hospital factors associated with aseptic revision after primary THA in patients registered in a large US Total Joint Replacement Registry. A total of 35,960 THAs registered from 4/2001–12/2010 were evaluated. The 8-year survival rate was 96.7% (95% CI 96.4%–97.0%). Females had a higher risk of aseptic revision than males. Hispanic and Asian patients had a lower risk of revision than white patients. Ceramic-on-ceramic, ceramic-on-conventional polyethylene, and metal-on-conventional polyethylene bearing surfaces had a higher risk of revision than metal-on-highly cross-linked polyethylene. Body mass index, health status, diabetes, diagnosis, fixation, approach, bilateral procedures, head size, surgeon fellowship training, surgeon and hospital volume were not revision risk factors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.