Abstract

Preoperative templating needs to be precise to optimize hip arthroplasty outcomes. Unexpected implant mismatches can occur despite meticulous planning. We investigated the risk factors for oversized and undersized stem mismatch during uncemented hemiarthroplasty using a double-tapered wedge rectangular stem for femoral neck fracture. Out of 154 consecutive patients who underwent hemiarthroplasty for femoral neck fracture, 104 patients were divided into three groups: (1) oversized (n = 17; 16.3%), (2) matched (n = 80; 76.9%), and (3) undersized stem group (n = 7; 6.7%). A smaller femoral head offset (odds ratio [OR] = 0.89, 95% confidence interval [95% CI] = 0.81–0.98, P = 0.017), smaller isthmus diameter (OR = 0.57, 95% CI = 0.35–0.92, P = 0.021), and smaller canal flare index (OR = 0.20, 95% CI = 0.04–0.98, P = 0.047) were significantly associated with oversized stem insertion, while older age (OR = 1.18, 95% CI = 1.01–1.39, P = 0.037) was associated with undersized stem insertion in logistic regression. In conclusion, when performing hemiarthroplasty for a femoral neck fracture with a double-tapered wedge rectangular stem, surgeons must pay close attention to proximal femoral geometry and patient age during preoperative planning to avoid stem mismatch.