The objective of this retrospective study was to identify risk factors for screw migration after triple pelvic osteotomy (TPO) in clinical patients. The medical records, radiographs made immediately after surgery, and follow-up radiographs documenting a healed osteotomy were reviewed for 52 dogs treated with unilateral TPO and 38 dogs treated with bilateral TPO. Signalment, surgeon expertise, length of surgery, sequence of surgery in dogs treated bilaterally, use of ischial or ilial wires or both, screw depth in the sacrum, and screw migration were documented for each of the 128 pelvic osteotomies. Screws placed in the first and second plate hole, securing the cranial portion of the plate, loosened most frequently. Factors associated with decreased screw migration included use of an ischial hemicerclage wire and increased depth of sacral purchase with the first and second cranial screws.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.