Abstract

BackgroundPhlebitis is an important complication occurring in patients with peripheral intravascular catheters (PIVCs). The risk factors for phlebitis in the intensive care unit (ICU) was examined.MethodsA secondary analysis of a prospective multicenter cohort study was conducted, involving 23 ICUs in Japan—the AMOR–VENUS study. Consecutive patients aged ≥ 18 years admitted to the ICU with newly inserted PIVCs after ICU admission were enrolled. Characteristics of the ICU, patients, PIVCs, and the drugs administered via PIVCs were recorded. A marginal Cox regression model was used to identify the risk factors associated with phlebitis.ResultsA total of 2741 consecutive patients from 23 ICUs were reviewed for eligibility, resulting in 1359 patients and 3429 PIVCs being included in the analysis population. The median dwell time was 46.2 h (95% confidence interval [CI], 21.3–82.9). Phlebitis occurred in 9.1% (95% CI, 8.2–10.1%) of catheters (3.5 cases/100 catheter days). The multivariate analysis revealed that the only factors that increased the risk of developing phlebitis were drugs administered intravenously. This study included 26 drugs, and 4 were associated with increased phlebitis: nicardipine (HR, 1.85; 95% CI, 1.29–2.66), noradrenaline (HR, 2.42; 95% CI, 1.40–4.20), amiodarone (HR, 3.67; 95% CI, 1.75–7.71) and levetiracetam (HR, 5.65; 95% CI, 2.80–11.4). Alternatively, factors significantly associated with a reduced risk of phlebitis were: standardized drug administration measures in the ICU (HR, 0.35; 95% CI, 0.17–0.76), 30≤ BMI (HR, 0.43; 95% CI, 0.20–0.95), catheter inserted by a doctor as nurse reference (HR, 0.55; 95% CI, 0.32–0.94), and upper arm insertion site as forearm reference (HR, 0.52; 95% CI, 0.32–0.85). The nitroglycerin was associated with a reduced phlebitis risk (HR, 0.22; 95% CI, 0.05–0.92).ConclusionVarious factors are involved in the development of phlebitis caused by PIVCs in critically ill patients, including institutional, patient, catheter, and drug-induced factors, indicating the need for appropriate device selection or models of care in the ICU.Trial registration: UMIN-CTR, the Japanese clinical trial registry (registration number: UMIN000028019, July 1, 2017).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.