Abstract

Non-invasive ventilation (NIV) has been widely used in hypoxemic acute respiratory failure (ARF) due to influenza pneumonia in the emergency department (ED). However, NIV used in influenza-associated acute respiratory failure had a variable rate of failure. Previous studies have reported that prolonged use of NIV was associated with increased mortality. Our study aimed to identify risk factors for NIV failure in influenza infection with acute respiratory failure in ED. We performed a retrospective cohort observational study. Enrolled patients were older than 18years who used NIV due to influenza infection with ARF between 1 January 2017 to 31 December 2018 in Ramathibodi Emergency Department. Patients characteristics, comorbidity, clinical, laboratory outcome, chest imaging, initial NIV setting, and parameters were collected in ED setting. Sequential organ failure assessment (SOFA) score and PaO2/FiO2 (PF) ratio were calculated from the first arterial blood gas in ED. We followed the outcome success or failure of the NIV used. A total of 162 patients were enrolled and 72 (44%) suffered NIV failure in influenza infection with ARF. We used univariate and multivariate logistic analyses to assess risk factors for NIV failure. The ability of risk factor to predict NIV failure was analyzed using the area under the receiver operating characteristic (AUROC). Risk factors of NIV failure included SOFA score (P=0.001), PF ratio (P=0.001) and quadrant infiltrations in chest x-rays (CXR) (P=0.001). SOFA score, PF ratio, and number quadrant infiltrations in chest radiography have good ability to predict NIV failure, AUROC 0.894 (95%CI 0.839-0.948), 0.828 (95%CI 0.764-0.892), and 0.792 (95%CI 0.721-0.863), respectively and no significant difference in the ability to predict NIV failure among three parameters. The use of PF ratio plus number quadrant infiltrations in chest radiography demonstrated a higher predictive ability for NIV failure in influenza infection with ARF. SOFA score, PF ratio, and quadrant infiltrations in chest radiography were good predictors of NIV failure in influenza infection with ARF.

Highlights

  • Non-invasive ventilation (NIV) has been widely used in hypoxemic acute respiratory failure (ARF) due to influenza pneumonia in emergency department (ED)

  • Influenza infection is a course of acute respiratory failure (ARF)

  • In patients with acute respiratory failure due to influenza infection admitted to intensive care unit (ICU), the intubation rate is high (60%) and mortality rate after intubation of up to 50% [1,2,3,4]

Read more

Summary

Objectives

The aim of this study was to identify risk factors associated NIV failure in ARF due to influenza infection in ED This study aimed to identify risk factors associated NIV failure in ARF due to influenza infection in ED

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.