Abstract

Esophageal safety following radiofrequency (RF) left atrial (LA) linear ablation has not been established. To determine the esophageal safety profile of LA linear RF lesions, we performed systematic esophagogastroduodenoscopy in all patients with intraesophageal temperature rise (ITR) ≥ 38.5°C. Between December 2021 and July 2023, a total of 200 consecutive patients with atrial tachyarrhythmia (ATA) underwent linear ablation with posterior dome (roof or floor) or posterior mitral isthmus line transection. Patients with ITR ≥ 38.5°C were scheduled for esophageal endoscopy ~3 weeks after ablation. Patient and ATA characteristics, procedural parameters, endoscopy findings and ablation lesion data were collected and analyzed. One hundred thirty-threeout of 200 (67%) patients showed ITR ≥ 38.5°C during LA linear ablation. ITR (with maximal temperature of 45.7°C) was more frequently observed during floor line ablation (82% of cases). ITR was less observed during roof line ablation (34%) and posterior mitral isthmus ablation (4%). Endoscopy, performed in 115 patients after 24 ± 10 days, showed esophageal ulceration in four patients (two patientsKansas City classification [KCC] 2a and two patients KCC 2b). No patient showed esophageal perforation or fistula. Temperature rise during LA linear ablation is frequent and ulceration risk exists, particularly when floor line is performed. Safety measures are needed to avoid potential severe complications like esophageal perforation and fistula.