Abstract

Dynamic simulations of distillation columns are widely used to develop effective control structures. The normal distillation models assume instantaneous heat transfer in the condenser and reboiler. However, when dynamic simulations are used in the analysis of safety problems in the event of emergency situations, the basic model does not accurately represent the dynamic response. Accurate response times are essential in the design of safety systems for the column. For example, a failure of the supply of cooling water will lead to rapid increases in pressures and temperatures that occur in seconds. Accurately determining the rates of increase in these important variables and the time period to reach critical limits (safety response time) permits the engineer to quantitatively design effective safety systems.This paper illustrates how rigorous condenser and reboiler models can be developed in Aspen Plus and their dynamics evaluated in Aspen Dynamics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.