Abstract

Background: In Computed Tomography (CT), it is often not possible for the subject to remain stationary during a scan. Unfortunately, a patient motion would result in degraded spatial resolution and image artifacts. It is desirable to improve reconstruction quality and reduce motion artifacts caused by patient motion. Methods: In this work, a method was proposed to eliminate the influence of the motion on image quality, based on the phase correlation method. Based on our previous work, projections were first taken by Radon transform and motion parameters were estimated by the phase-only correlation of projections in the Radon domain. In addition, an improved image reconstruction algorithm was performed to compensate for the motion effects. Results: Experimental results proved that the proposed method could not only obtain high precision and good real-time performance but also ensure a superior artifact reduction. Conclusion: Besides, the efficacy of the proposed method has been demonstrated in both simulated and human head experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.