Surgical skill and strategy for the correction of tetralogy of Fallot (TOF) have improved and resulted in satisfactory outcomes. However, prematurity and low birth weight continue to remain risk factors for poor outcomes. We present a case of a 2,150 g neonate born with TOF, in whom palliation was achieved with right ventricular outflow tract (RVOT) stenting. Seventy-seven days after the procedure, stenosis of RVOT below the stent was identified. At that time his body weight was 4.9 kg and total corrective surgery was deemed feasible. Eight months following surgical repair, the patient remained well without medical intervention. RVOT stenting may be a viable interim procedure while waiting for a low birth weight neonate born with TOF and prostaglandin E1 dependency to reach optimal weight to undergo corrective surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.