Abstract Funding Acknowledgements Type of funding sources: None. Introduction Pacemaker’s ventricular sensing function relies on the analysis of the intracardiac electrogram (EGM) including the timing of the intrinsic detection. The phenomenon of ventricular sensing latency refers to the gap of time by which the intrinsic signal gets delayed to be detected compared with the surface electrogram (ECG). A pacing system analyzer (PSA) unit is needed to record the EGM during pacemaker operation, which is expected to correspond to those taken following implantation. Purpose We sought to determine the latency period for sensing EGM by the right ventricular (RV) lead, either through the PSA or through the implanted pacemaker on the same patient. Methods Patients without significant heart disease and intrinsic atrioventricular conduction underwent conventional dual-chamber Medtronic or Abbott pacemaker implantation with the RV lead positioned on mid-septum. Real time sensing data was obtained through PSA and after pacemaker implantation. The RV lead sensing latency was defined as the time interval Q-VS measured from the beginning of QRS on ECG to the released ventricular sensed (VS) event marker on either device. Results Of 157 patients, 105 had narrow QRS (<120 ms) and 52 had wide QRS (≥120 ms) of right bundle branch block (RBBB). Both narrow QRS and RBBB patients had longer sensing latency through PSA (50.9 ± 24.2 ms and 67.8 ± 32.9 ms, respectively) than through pacemaker (18.2 ± 12.8 ms and 31.2 ± 14.8 ms, respectively, both p<0.001). RBBB patients had longer sensing latency compared with narrow QRS patients, either through PSA or through pacemaker (p<0.001). The sensing latency of Medtronic recipients was longer than those of Abbott in narrow QRS, but not in RBBB (p=0.03 and p=0.08, respectively). Conclusion We demonstrated longer RV lead sensing latency (1) through PSA than through the implanted pacemaker, (2) in RBBB than in narrow QRS, (3) in Medtronic pacemakers compared with Abbott pacemakers. Knowledge of the RV lead sensing latency helps optimization of atrioventricular delay and reduces unnecessary ventricular pacing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.