Abstract

Results:The 6-MWT distance correlated with t-IVT and Tei index (r=-0.37, p<0.001, for both), lateral and septal e’ velocities (r=0.41, p<0.001, and r=0.46, p<0.001, respectively), E/e’ ratio (r=-0.37, p<0.001) and TAPSE (r=0.45, p<0.001), but not with the other clinical or echo parameters. Group I patients had longer t-IVT, lower E/e’ratio, TAPSE and lateral e’ (p<0.001 for all) compared with Group II. In multivariate analysis, TAPSE [0.076 (0.017-0.335), p=0.001], E/e’ [1.165 (1.017-1.334), p=0.027], t-IVT [1.178 (1.014-1.370), p=0.033] independently predicted poor 6-MWT performance (<300 m). Sensitivity and specificity for TAPSE 1.9 cm were 66% and 77%, (AUC 0.78, p<0.001); E/e’ 10.7 were 66% and 62% (AUC 0.67, p=0.002) and t-IVT 13 s/min were 64% and 60% (AUC 0.68, p=0.002) in predicting poor 6-MWT. Combined TAPSE and E/e’ had a sensitivity of 68% but specificity of 92% in predicting 6-MWT. Respective values for combined TAPSE and t-IVT were 71% and 85%. Conclusion:In patients with HF, the limited exercise capacity assessed by 6-MWT, is multifactorial being related to severity of right ventricular systolic dysfunction as well as raised LV filling pressures and global dyssynchrony.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.