Abstract

With larger blood volume flowing into a cardiac chamber, by stretching muscle fibers, increased contraction force could be detected. This phenomenon is called Frank-Starling mechanism, allowing the output of a cardiac chamber to be synchronized without external regulation. The purpose of the present study was to investigate the Frank-Starling mechanism in the right atrium (RA) represented by its volumes, volume-based functional properties and strains respecting the cardiac cycle in healthy adults by three-dimensional (3D) speckle-tracking echocardiography (3DSTE). The present single center retrospective cohort study comprised 179 healthy adult volunteers (mean age: 33.2±12.0 years, 92 males), in whom complete two-dimensional Doppler echocardiography with 3DSTE was performed. Subjects were divided into 3 groups according to the mean value of maximum RA volume (Vmax) ± standard deviation: Vmax <30 mL, 30 mL ≤ Vmax <60 mL and Vmax ≥60 mL. All RA volumes respecting the cardiac cycle of all subjects and calculated separately for females and males and their indexed equivalents increased with Vmax. RA stroke volumes increased with Vmax regardless of the phase it was measured in. While total atrial emptying fraction representing the reservoir phase remained unchanged with the increase of Vmax, a significant increase in passive atrial emptying fraction representing the conduit phase could be detected, in case of Vmax >60 mL (28.9%±15.1% vs. 32.5%±12.6%, P<0.05). Active atrial emptying fraction representing the booster pump function did not change with the increase of Vmax. Most global and mean segmental peak RA strains did not show significant changes with increasing RA volumes except for the RA area strain, it was the largest when Vmax was larger than 60 mL (64.7%±44.9% vs. 83.3%±49.4%, P<0.05). RA circumferential, longitudinal and area strains at atrial contraction decreased with increasing Vmax, RA radial and 3D strains did not change significantly with increasing Vmax. Increasing RA volumes do not cause significant increase in RA contractility represented by strains, but reduction in strains in longitudinal and circumferential directions could be detected in end-diastolic booster pump function. In contrast to the left atrium, obvious signs of Frank-Starling mechanism could not be detected in case of the RA.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.