Abstract

Foams are being used in a number of petroleum industry applications that exploit their high viscosity and low density. Foamed cement slurries can have superior displacement properties relative to non-foamed cement slurries. This article presents results of an experimental study of foamed cement rheology. Viscosity curves of foamed cements were obtained using a flow-through rotational viscometer. Foamed cements with different foam qualities were generated under different pressures using a foam generator/viscometer apparatus. The foam qualities during the tests ranged from 0% to 30%, and the shear rate varied between 5 s − 1 and 600 s − 1 . Experimental results indicate that: i) unlike conventional aqueous foams, low-quality cement foams have a lower viscosity than the base fluid; ii) as the cement foam quality (gas volumetric fraction) increases from 10% to 30%, the viscosity also increases; and iii) the viscosity of low-quality cement foam slightly increases after depressurization or expansion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.