Abstract

Plasma heating experiments at frequencies near the lower hybrid frequency have been carried out at modest powers (.05 to 4kW). The antenna structure operating at 68 MHz was comprised of two plates driven out of phase on the exterior of the plasma. High electron heating efficiency (greater than 40 percent) in both helium and argon plasmas was observed with only a weak density dependence. At low densities (n/sub e/ less than or equal to 1 x 10$sup 11$ cm$sup -3$), the heating was uniform across the plasma while at higher densities the heating was preferentially on the exterior portion of the plasma. The heating of the exterior of the plasma was found not to correspond to absorption at the lower hybrid resonance layer. The electron heating efficiency was found to be a weak function of rf power when the incident rf power was varied from 1 to 15 times the experimentally observed threshold power for parametric instabilities. Ion temperatures were determined by measuring the Doppler broadening of an Argon ion line using a Fabry-Perot interferometer. Low efficiency main body ion heating (1 to 3 percent) was observed. (auth)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call