Abstract
The 53.667 MHz continuous-wave heavy ion RFQ has been designed and manufactured for the SSC-LINAC project. This four-rod RFQ accelerates ions with maximum mass to charge ratio of 7 from 3.728 keV/u to 143 keV/u. Measurements have been carried out to check the RF performance of the cavity and the quality of the electric field. The S11 of the power coupler is adjusted to better than -44 dB, and the Q 0 of the cavity is 6440. The quality of the electric field is evaluated by the perturbation method. The measurement procedure and data analysis will be discussed in detail. The error due to gravity of the perturbation bead has been corrected by averaging the fields in different quadrants. As a result, the unflatness of the electric field is ±2.5%, and the dipole field component distributes from 0% to 20% in different longitudinal positions, which indicates the asymmetry of the quadrupole field. The unflatness of the quadrupole field distribution represents a good agreement with the simulation results. High power RF test and beam commissioning of the RFQ are on schedule in early 2014.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.