Abstract

In addition to periprosthetic infections (PJI), the reconstruction of bony defects is the major challenge of revision total knee arthroplasty (TKA). Infection should be ruled out in all cases prior to operation. Revision TKA requires intensive planning with regard to the needed augmentation possibilities and the stems to be used. The sole biological reconstruction of major defects (AORI II and III) shows high failure rates. Large defects must be augmented by metal (wedges/sleeves/cones). The concept of zonal anchorage (3-zone model) with a stable anchorage in 2 out of 3 zones as close to the joint as possible is currently the standard. According to the model, metaphysis (zone 2) is an increasingly important factor for long-term stable anchoring. The use of cones or sleeves seems to significantly improve the results of revision TKA. The anchorage in zone 3 via stems is still mandatory. Cemented metaphysary anchoring and cement-free diaphysary anchoring stems are available, whereby no clear recommendation for a principle can be given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.