Abstract

Designing Air Cleaning Units (ACU) of an Engineered Safety Feature and normal atmosphere clean-up system at the renovated APR-1000 and APR-1400 NPP, and fuel cycle facilities in Korea, is required to meet the standards of ASME AG-1 (1997), ASME N509/N510 (1989) and KEPIC-MH (2001) to enhance the removal efficiency of aerosols and particulates from the effluents. The revised ACU testing criteria are allowed to use alternative challenge agents of the dioctyl phthalate and Refrigerant-11 for in situ testing of high efficiency particulate air filters and adsorption banks. The operability testing time of engineered safety feature (ESF) trains was changed from 10 h to 15 min. The activated carbon in adsorption banks should undergo laboratory tests at a temperature of 30 °C and relative humidity 95 %. The removal criteria of methyl iodide should be over 99.5 % for ESF and 99 % for normal systems. This paper provides the background of the changed criteria for designing and testing of the ACU system in nuclear facilities.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.