Abstract

This study details a method using rapid prototyping (RP) technique to assist in acetabular revision with complex bone defects. Hemi-pelvic RP models were built among 25 patients with complex acetabular bone defects. Each patient was scheduled to undergo revision using either commercially available or customized cages based on individualized RP models. Average follow-up was 4.4 years (range, 1 to 9 years). The average Harris hip score was 36.1 (range, 20 to 58) preoperatively and reached an average of 82.6 (range, 60-96) at the last follow-up. No mechanical failure or loosening was observed. One patient experienced hip dislocation 4 days postoperatively. The resultant findings of this study merit consideration of RP as a helpful clinical complement for dealing with some complex bone defect of acetabulum.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.