Abstract

The use of ultrasound in differentiation of benign and malignant solid hypo-echoic thyroid nodules is a dilemma in clinical practice. The aim of this study was to investigate the revised value of contrast-enhanced ultrasound (CEUS) for differentiating solid hypo-echoic thyroid nodules using the Thyroid Imaging Reporting and Data System (TI-RADS).The study included 135 patients with 135 nodules confirmed by fine-needle aspiration and/or surgery. Every nodule underwent both conventional US and CEUS. Binary logistic regression analysis for conventional US features revealed that irregular shape, microcalcification and height greater than width were significant malignant predictive features. Binary logistic analysis for CEUS features indicated that hetero-enhancement, slow wash-in, an ill-defined enhancement border and fast wash-out were significantly associated with malignancy. The areas under the curve of the TI-RADS, CEUS and the combination were 0.806, 0.934 and 0.950, respectively. CEUS is a potentially useful tool in the differentiation of solid hypo-echoic thyroid nodules.