Abstract

Changes in the Canadian steel industry warrant a review of the steel resistance factor in CSA Standard S16 (formerly S16.1) "Limit states design of steel structures", originally calibrated in the landmark study by Kennedy and Gad Aly in 1980. This paper presents statistical parameters for the bending, compression, and tension resistances of W, WWF, and HSS components produced since 1999 that have been derived from geometric and material properties presented in a companion paper. The resistance factor for steel was recalibrated for the live and dead load combination in the 1995 National Building Code of Canada. A resistance factor of 0.95 is suitable for laterally supported beams, stocky columns, and tension members failing by yield of the gross section, whereas the current value of 0.90 is appropriate for intermediate columns and tension members failing by fracture of the net section.Key words: code calibration, member resistance, reliability, resistance factor, safety, structural steel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.