Abstract

In this study reversible and irreversible voltage loss in a polymer electrolyte membrane fuel cell undergoing an open circuit voltage (OCV) durability test was studied. OCV durability testing is thought to promote chemical degradation of the electrolyte membrane material via radical attack and degradation of the catalyst layer. The results for degradation under constant relative humidity showed that voltage degradation rates measured in the first 20–50 h after polarization curve measurement consisted of a reversible, or transient, and irreversible component. A steady voltage decay rate became evident after 50 h of operation. Comparison to the voltage decay rates obtained from polarization curves showed that the steady voltage decay rate was representative of irreversible voltage loss due to irreversible changes in materials as shown by crossover and active surface area measurements. This study highlights the necessity of understanding the difference between reversible and irreversible voltage decay rates since the reversible decay rates were found to be much higher than irreversible decay rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.