Abstract

Abstract A reverse osmosis process has been found to be effective for the separation of radiocontaminants from ammonium diuranate effluents in a uranium metal plant. Pilot-plant-scale experiments were conducted using cellulosic membranes in a plate module system and actual plant effluents containing more than about 40,000 ppm of ammonium and nitrate species and having radiocontaminants corresponding to specific activities of about 10−3 Ci/m3 beta/gamma emitters. The results indicated that more than 95% by volume of the treated effluents were within disposal limits, while the remaining contained the concentrate, which can be treated for possible containment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.