Abstract

A numerical simulation model for lateral capillary tube-suction line heat exchangers is presented here to analyze its performance characteristics in small vapour compression refrigeration systems (e.g. domestic refrigerators). Appropriate heat transfer correlations have been used to illustrate the reverse heat transfer and re-condensation phenomena inside the tubes. Some convergence problems were encountered during the execution of the model when lower vapour temperature inside the suction line caused the two-phase refrigerant inside the capillary tube to re-condense within the heat exchange region. Therefore, a relationship between the re-condensation phenomenon and the divergence problem has been analyzed in the paper. The modelling was performed with two refrigerants, namely HFC-134a and HC-600a. Further, a simple theoretical equation has been developed to express the re-condensation phenomenon in non-adiabatic capillary tubes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.