AbstractOn the basis of known geometry, loads, and materials but with incomplete design details, the structure of a certain tall building was recreated. The first phase was a series of hand calculations to initially estimate the necessary cross sections. Then, a global finite-element (FE) model of the building was constructed and subjected to gravity and wind forces. Of particular interest were the peripheral H-shaped columns located immediately inside the glass curtain. The detailed FE buckling models of those columns were created and subjected to moderately dynamic axial loading. The analyses were carried out for an average-sized column section, and its results are discussed here. Two types of models were used in the FE work, shell and solid models. Although the magnitude of the buckling force was obviously set by the design requirements, the postbuckling characteristic was of interest, because it could play a role under some extreme loading conditions. The properties of the column material, namely, hig...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.