Abstract

BackgroundThe principle of acetabular total hip revision (THR) is based on acetabular reconstruction and restoration of the center of rotation. The use of augmentation in high cranial acetabular defects combined with a cementless revision shell was studied sufficiently. This study aimed to report a case with the use of an augment inside a cementless revision shell as a reverse augmentation technique.MethodsWe describe the case of an 86-year-old female patient with a massive acetabular defect during second revision for total hip arthroplasty (THA). Two problems occurred: (1) a fixed cemented stem with a nonmodular head size of 33 mm and (2) a high acetabular defect with an elevated rotation center.ResultsWith the distraction technique, allograft filling was used to reconstruct the acetabular defect. A cementless revision shell (REDAPT, Smith and Nephew) with a size of 78 mm was used to stabilize the defect. Locking screws placed cranially and distally were used to stabilize the cup for secondary osseointegration. An augment was placed inside the cup to reconstruct the rotation center. A customized polyethylene liner (outer diameter, 54 mm/inner diameter, 33 mm) was positioned below the augment in the revision cup to reconstruct the center of rotation. An 18-month postoperative X-ray analysis showed a stable construct with full secondary osseointegration.ConclusionThis is the first report of an augment used for a reverse technique inside a cementless shell to restore the center of rotation with the use of a customized polyethylene liner. This might be a reliable option for reconstruction of the center of rotation in large cementless revision cups in acetabular Paprosky type III defects. This technical note shows the possibility of using an augment as a reverse technique in a cementless revision cup.

Highlights

  • The principle of acetabular total hip revision (THR) is based on acetabular reconstruction and restoration of the center of rotation

  • Acetabular revision arthroplasty is based on three main principles

  • Different implant designs and sizes are available for total hip arthroplasty (THA) acetabular revisions [1]

Read more

Summary

Introduction

The principle of acetabular total hip revision (THR) is based on acetabular reconstruction and restoration of the center of rotation. The use of augmentation in high cranial acetabular defects combined with a cementless revision shell was studied sufficiently. This study aimed to report a case with the use of an augment inside a cementless revision shell as a reverse augmentation technique. The first is the primary stable fixation of the revision cup in the acetabular defect after second principle, which is bony reconstruction. Götze and Peterlein Journal of Orthopaedic Surgery and Research (2020) 15:396. Case This case report aimed to reconstruct a highly acetabular defect in an 86-year-old female patient.

Objectives
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.