Arrays of aligned single-walled carbon nanotubes (SWCNTs) produced by supergrowth method were studied by scanning electron microscopy (SEM) and angle-resolved near-edge X-ray absorption fine structure spectroscopy, which defined that nanotube disorder is 10–13° and 23–27°, respectively. The latter value was confirmed by X-ray fluorescent spectroscopy. The difference in the obtained angular deviations was attributed to distortion of the SWCNT walls, because the X-ray spectroscopy methods are sensitive to a local environment of probing atoms, while the SEM examines the nanotubes at a substantially larger length scale. Significant distortion (20–24°) of SWCNT walls could be related to the defects introduced during the growth process.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.