Abstract

BackgroundMultidetector computed tomography (MDCT) plays a key role in patient assessment prior to transcatheter aortic valve implantation (TAVI). However, to date no consensus has been established on what is the optimal pre-procedural imaging protocol. Variability in pre-TAVI acquisition protocols may lead to discrepancies in aortic annulus measurements and may potentially influence prosthesis size selection.PurposeThe current study evaluates the magnitude of differences in aortic annulus measurements using max-systolic, end-diastolic, and non-ECG-synchronized imaging, as well as the impact of method on prosthesis size selection.Material and methodsFifty consecutive TAVI-candidates, who underwent retrospectively-ECG-gated CT angiography (CTA) of the aortic root, directly followed by non-ECG-synchronized high-pitch CT of the entire aorta, were retrospectively included. Aortic root dimensions were assessed at each 10% increment of the R-R interval (0–100%) and on the non-ECG-synchronized scan. Dimensional changes within the cardiac cycle were evaluated using a 1-way repeated ANOVA. Agreement in measurements between max-systole, end-diastole and non-ECG-synchronized scans was assessed with Bland-Altman analysis.ResultsMaximal dimensions of the aortic root structures and minimum annulus-coronary ostia distances were measured during systole. Max-systolic measurements were significantly and substantially larger than end-diastolic (p<0.001) and non-ECG-synchronized measurements (p<0.001). Due to these discrepancies, the three methods resulted in the same prosthesis size selection in only 48–62% of patients.ConclusionsThe systematic differences between max-systolic, end-diastolic and non-ECG-synchronized measurements for relevant aortic annular dimensions are both statistically significant and clinically relevant. Imaging strategy impacts prosthesis size selection in nearly half the TAVI-candidates. End-diastolic and non-ECG-synchronized imaging does not provide optimal information for prosthesis size selection. Systolic image acquisition is necessary for assessment of maximal annular dimensions and minimum annulus-coronary ostia distances.

Highlights

  • Multi-detector row computed tomographic (MDCT) assessment of the aortic root plays an important role in pre-procedural planning of transcatheter aortic valve implantation (TAVI) [1,2,3]

  • The current study evaluates the magnitude of differences in aortic annulus measurements using max-systolic, end-diastolic, and non-ECG-synchronized imaging, as well as the impact of method on prosthesis size selection

  • Maximal dimensions of the aortic root structures and minimum annulus-coronary ostia distances were measured during systole

Read more

Summary

Introduction

Multi-detector row computed tomographic (MDCT) assessment of the aortic root plays an important role in pre-procedural planning of transcatheter aortic valve implantation (TAVI) [1,2,3]. Aortic root dimensions need to be accurately assessed in order to evaluate patient suitability for the procedure[4, 5], as well as for optimal prosthesis type and size selection[3, 5]. The only prerequisite is that motion-free images of the aortic root have to be acquired This ambiguity has led to the introduction of a variety of pre-TAVI protocols, in which aortic root dimensions are assessed at different time points of the cardiac cycle. The current study evaluates the magnitude of differences in aortic annulus measurements using max-systolic, end-diastolic, and non-ECG-synchronized imaging, as well as the impact of method on prosthesis size selection

Methods
Discussion
Conclusion