Abstract

Purpose: Implant subsidence is a possible complication of spinal interbody fusion. We aim to evaluate porous titanium cages subsidence, fusion and functional outcomes in patients subjected to oblique lumbar interbody fusion (OLIF) with these novel devices. Methods: Our institutional review board approved a single-center experience which included 60 patients who underwent OLIF from June 2018 to June 2020 utilizing the porous titanium implants. Data was collected in accordance with the Declaration of Helsinki, and written informed consent was obtained. Imaging studies including radiographs 1, 3, 6 and 12 months and computed tomography (CT) scan at 6 months obtained during routine postoperative follow-up visits, were studied for signs of implant subsidence, fusion and clinical parameters to determine the effectiveness of surgery such as Oswestry disability index (ODI). Results: Radiographic subsidence occurred in 1 out of 89 porous titanium interbody cages (1.1%). No subsidence was observed in the posterior screws and rods fixation group (N = 57). However, one case of subsidence occurred in the lateral plate fixation group (N = 3). The subsidence occurred in an osteoporotic elderly patient operated for adjacent segment disease, and she was later revised with posterior instrumentation using cemented screws and rods. She had an uneventful recovery. Fusion rates were evaluated under CT scan at 6 months with a rate of 88%. In terms of clinical outcomes, ODI decreased significantly from 20.3 preop to 10.7 postop with a P-value < 0.05. Conclusions: In our study, the subsidence rate was lower than previously reported in the literature. Also, we had good fusion rates at 6 months likely due to the porous titanium cages use. We had no subsidence in the posterior instrumented group and one case in the lateral fixation group with improved clinical outcomes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call