Abstract

This study aimed to clinically and radiographically evaluate the results of guided bone regeneration (GBR) using three-dimensional preformed titanium mesh (3-D-PFTM) for non-contained horizontal defects in 100 consecutive cases. This study involved 100 patients (129 implants) with peri-implant non-contained horizontal defects. The patients were divided into three groups: 3-D-PFTM alone (Group 1), 3-D-PFTM plus cross-linked collagen membrane (Group 2), and 3-D-PFTM plus non-cross-linked collagen membrane (Group 3). Each implant was evaluated radiographically using CBCT at baseline and 6 months postoperatively. At the platform level, the mean horizontal hard tissue gain of all the sites was 3.1 ± 1.3 mm at 6 months postoperatively. The mean rate of mesh exposure was 11.8% in Group 1, 4.2% in Group 2, and 5.0% in Group 3. The mean hard tissue gain rate was 71.0 ± 23.0% in group 1, 84.2 ± 21.5% in group 2, and 84.0 ± 22.9% in group 3. Groups 2 and 3 showed significantly higher hard tissue gain rates than group 1. However, there was no significant difference between the rates in groups 2 and 3. Within the limitations of this study, 3-D-PFTM should be considered as a valuable option for GBR for peri-implant non-contained horizontal defects. The use of an additional resorbable collagen membrane provides additional advantages.

Highlights

  • Horizontal or vertical bone mass is often insufficient, and various techniques have been introduced for atrophic alveolar bones, including autologous onlay block bone graft, sinus floor elevation, rigid splitting, and guided bone regeneration (GBR) [2,3,4,5]

  • Cone‐beam computed tomography (CBCT) was performed for all the implants, under the same imaging conditions (FOV diameter, 10 cm; FOV height, 5.6 cm; acceleration voltage, 90 kV; beam currency, 8.0 mA; voxel size, 0.2 mm), preoperatively and immediately and six months after the first surgery

  • Cross-sectional CT images across the center of the implant in the metrology program (OnDemand 3-DTM; Cybermed, Seoul, Korea) were used to compare the amount of bone acquired from the non-contained horizontal defects, and the line perpendicular to the long axis of the implant was extended from the platform level to the buccal side to measure the distance to the outermost bone on the extension line (Figure 2)

Read more

Summary

Introduction

Ti-mesh; a dentist can improve the prognosis of guided bone regeneration, especially for peri-implant non-contained defects. This study aimed to clinically and radiographically evaluate the results of guided bone regeneration (GBR) using three-dimensional preformed titanium mesh (3-D-PFTM) for non-contained horizontal defects in 100 consecutive cases. This study involved 100 patients (129 implants) with peri-implant non-contained horizontal defects. The mean horizontal hard tissue gain of all the sites was 3.1 ± 1.3 mm at 6 months postoperatively. The mean hard tissue gain rate was 71.0 ± 23.0% in group 1, 84.2 ± 21.5% in group 2, and 84.0 ± 22.9% in group 3. Within the limitations of this study, 3-D-PFTM should be considered as a valuable option for GBR for peri-implant non-contained horizontal defects.

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.