Abstract

Flexible fibreoptic laryngoscopy is the method of choice for coping with difficult tracheal intubations, a leading cause of catastrophic outcomes in anaesthesia. However, this technique is not always available or feasible. Retrograde intubation is a minimally invasive airway management technique with a flat learning curve and a high level of skill retention. A retrospective review of the anaesthesia records of 24 patients who underwent retrograde intubation. The success rate and the incidence of complications were recorded. Retrograde tracheal intubation was successful in all 24 patients. In 21 patients it succeeded on the first attempt. In two patients it succeeded when the technique was changed from sliding over a guide wire to a pulling technique. The most common complication was a sore throat in almost 60% of the patients. Two patients had mild subcutaneous emphysema and one had minimal bleeding at the puncture site. In these patients retrograde tracheal intubation was easy to perform, had a high success rate and a low incidence of complications. It is a reliable alternative when fibreoptic intubation is precluded, fails or is unavailable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.