Abstract

To the Editor The Frova intubating introducer with an angled flexible tip and rigid internal stylet was designed for difficult orotracheal intubations. Here we report the novel use of the Frova intubating introducer for retrograde intubation via a caudally directed tracheostomy tract in a patient in whom antegrade intubation had been unsuccessful. A 59-year-old male quadriplegic patient with a tracheostomy was diagnosed with tracheoesophageal fistula and admitted to the operating room for fistulectomy. The patient had undergone cervical spine surgery after a car accident 9 years ago and presented with severely wasted neck and limbs, a large tongue, and a <1-cm mouth opening. For the fistulectomy, oronasotracheal intubation was needed because the tracheoesophageal fistula was just 1 cm above the tracheostomy site. We attempted nasal fiberoptic bronchoscope-guided intubation under light sedation, but the narrowness of the oral cavity and a large amount of secretions made it difficult to pass the fiberoptic bronchoscope beyond the tongue base. We therefore decided to try retrograde intubation through the tracheostomy opening. We attempted to insert a Cook airway exchange catheter (Cook Critical Care, Letchworth, Hertfordshire, UK) ordinarily used as a “guidewire” for retrograde intubation, via the tracheostomy tract several times, but the tip failed to advance cephalad. Alternatively, we inserted a Frova intubating introducer (Cook Critical Care) with a rigid internal stylet into the tracheostomy tract, and after advancing the angled tip 5 cm in the cephalad direction, the stylet was removed. We kept advancing the Frova intubating introducer into the pharyngeal space. The distal tip emerged from the left nostril, and then retrograde intubation was successfully conducted by using the introducer as a guide. Insertion of a flexible guide for retrograde intubation via a tracheostomy with a caudal orientation of the internal tracheal lumen results in advancement of the guide further into the trachea rather than cephalad through the larynx. In our case, because the Cook airway exchange catheter, initially used as a guide, was flexible and did not have an angled tip, it could not be advanced in the cephalad direction via the caudally directed tracheostomy tract, causing our initial attempt at retrograde intubation to fail (Fig. 1). However, the Frova intubating introducer is made of more rigid polyethylene and has a length of 65 cm, an outside diameter of 4.7 mm, a tip portion of approximately 2 cm with a flexible angle of 65°, and an internal stylet that can be inserted for rigidity up to the distal 5 cm.1 These features account for why we were able to advance the Frova intubating introducer in the cephalad direction via a caudally oriented tracheostomy tract (Fig. 2). Retrograde intubation using an intubating introducer via a tracheostomy is not a recommended technique and could result in creation of a false passage, vocal cord injury, retropharyngeal hematoma, and tissue damage.2 Because our patient had maintained a tracheostomy for over 8 years, the risk of a false passage was relatively low.Figure 1: The Cook airway exchange catheter was unable to be advanced in the cephalad direction via a caudally oriented tracheostomy tract with a hyperacute angle.Figure 2: A, The Frova intubating introducer with an angled flexible tip and rigid internal stylet. B, (a) The angled tip of the Frova intubating introducer is inserted in the cephalad direction. (b) The Frova intubating introducer is advanced while carefully applying lever-like force in the caudal direction. C, The Frova intubating introducer is successfully advanced in the cephalad direction with a retraction movement while removing the internal stylet at the same time.PATIENT CONSENT STATEMENT Published with the written consent of the patient's family and the approval of the Institutional Review Board (ref. 4–2011-0554) of Yonsei University Health System. Shin Hyung Kim, MD Yong Seon Choi, MD, PhD Young Jun Oh, MD, PhD Department of Anesthesiology and Pain Medicine Anesthesia and Pain Research Institute Yonsei University College of Medicine Seoul, Korea [email protected] ACKNOWLEDGMENTS The authors are grateful to Dong-Su Jang, Research Assistant, for his help with the figures in the article.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call