Abstract

Ultra High-Performance Fiber Reinforced Concrete (UHPFRC) is a cementitious composite that exhibits superior mechanical properties, durability, fire resistance, abrasion resistance, and chloride penetration. The enhanced performance of UHPFRC is attributed to the presence of highstrength steel fibers. Therefore, UHPFRC is widely used in structural retrofitting and rehabilitation works to improve the load carrying capacity of deteriorated structural members. This paper investigates the behaviour of UHPFRC retrofitted shear critical reinforced concrete beams. Numerical models were developed to simulate how the load-carrying capacity of UHPFRC retrofitted shear critical beams is influenced by factors such as jacket configuration, jacket thickness, and jacket length along the beam. Numerical models were validated using pre-existing experimental results. A modified Concrete Damage Plasticity (CDP) model was employed to simulate the material behaviour of UHPFRC. The validated numerical model was employed to perform parametric studies to examine the behaviour of UHPFRC retrofitted beams. It was observed that the modified CDP model effectively predicted the UHPFRC behaviour. Further, the results indicated that the application of UHPFRC retrofitting converted the brittle shear failure of shear-critical reinforced concrete beams into flexure failure. Moreover, the load carrying capacity of retrofitted beams increased with the retrofitted UHPFRC jacket thickness.