Abstract

AbstractCover plates are often added to existing (loaded) steel columns as an effective retrofit method for increasing their compressive design strength. Current bridge design specifications provide equations for calculating the compressive design strength of steel columns. However, these equations cannot be extended to calculate the design strength of retrofitted columns because they do not account for the effects of cover plates added to the existing loaded members. The authors previously investigated the fundamental behavior of retrofitted built-up steel double-box columns using the finite-element analysis approach and also developed and benchmarked a nonlinear inelastic column buckling (NICB) analysis approach that accounts for the mechanics of existing (loaded) built-up steel columns retrofitted by added cover plates. This paper presents the results of comprehensive parametric studies conducted using the benchmarked NICB analysis approach to evaluate the behavior and strength of retrofitted steel col...