Abstract

For full use of low heat value of coke oven gas and operation under conditions of coal, gas and coal/gas, a previously 75t/h PC-fired boiler was retrofitted: six gas burners with dual-passage were installed under the originally PC-fired burners and tangentially arranged with a larger combustion circle and declined axes; the pulverized coal fired burners were declined downward 8∼10° so as to control the flame center; the heating surface of slag cooling tube and economizer were extended. The operation and test after the retrofit showed that: the combustion was very stable and temperature of the superheated steam was between the normal range under all conditions of load and fuel; the maximum steam rate was 59t/h and temperature of the exhaust flue gas was lower than 160°C under gas condition while gas flow was at 26000 Nm3/h; the maximum steam rate was 81t/h and temperature of the exhaust flue gas was lower than 147°C under coal condition; the maximum steam rate was 77t/h and temperature of the exhaust flue gas was about 155°C under coal/gas condition.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.