Abstract

Diaphragm cutouts are set to release redundant constraints and hence reduce weld fatigue at the connection of U-ribs to diaphragms in orthotropic steel decks. However, most fatigue cracks which originate from the edge of cutouts are in fact detected in the diaphragms. Therefore, a retrofit technology on cracked cutouts at the diaphragm is proposed and applied to the orthotropic steel box girder of a suspension bridge. Firstly, the stress concentration on the cutout is analyzed through refined finite element analyses. Furthermore, the fatigue cracked cutouts are retrofitted by changing their geometrical parameters. Thereafter, an optimized geometry and the size of diaphragm cutouts were confirmed and applied in the rehabilitation of a suspension bridge. On-site wheel load tests were carried out before and after retrofitting of the diaphragm cutout. The stress distributions along the edges of the cutouts and at the side of a diaphragm were measured under a moving vehicle. The stress spectra at two critical locations on the edge of a cutout was obtained under longitudinally and laterally moving vehicles. Finally, the fatigue life of the cutouts is assessed by the modified nominal stress method. The analytical and test results indicate that the wheel loads on the deck transmit stress to the diaphragms through the U-ribs, during the load transmission process, the stress flow is obstructed by diaphragm cutouts, resulting in local stress concentrations around the cutouts. In addition, the overall size of the cutouts should be small, but the radius of the transition arc should be large, thus the stress flow will not be obviously obstructed. After the retrofitting of the cutouts by improved geometry, the maximum stress decreases by 87.6 MPa, which is about 40% of the original stress. The equivalent constant amplitude stress is reduced by 55.2% when the lateral position of the wheel loads is taken into consideration. Based on the stresses obtained by finite element analysis (FEA) and experimental tests, the fatigue lives of the original cutouts are 1.7 and 4.9 years, respectively, which increase to 78.1 and 155.5 years, respectively, after the cutouts were retrofitted, which indicates that the improved geometry and retrofit technology can enhance the fatigue performance and extend the fatigue life of diaphragm cutouts with fatigue cracks.

Highlights

  • Orthotropic steel decks (OSDs) are widely used in cable supported bridges and girder bridges due to their light weight and the short onsite construction time [1,2,3]

  • This paper explores the stress concentration mechanisms around diaphragm cutouts using stress flow methods, based on an in a suspension bridge that had developed fatigue cracks during flow methods, based on an OSD in a suspension bridge that had developed fatigue cracks during its its service period, years of operation

  • From the test and finite element analysis (FEA) results, it can be found that: the rear axis were located on either side of the test diaphragm at equal spacing (0.75 m)

Read more

Summary

Introduction

Orthotropic steel decks (OSDs) are widely used in cable supported bridges and girder bridges due to their light weight and the short onsite construction time [1,2,3]. Several types of fatigue cracks occur at the edges of added holes and at welded joints in OSD bridges [4,5,6]. The types of cracks that originate from the edges of diaphragm cutouts at the connections of U-ribs to diaphragms account for 42.3% to 85.5% of the total number of fatigue cracks in OSDs [4,5,6,7,8,9,10]. Sci. 2020, 10, 3983 of timely and essential retrofits causes these cracks to elongate and propagate throughout the entire diaphragm, which decreases the serviceability of OSDs, and reduces the service life and safety of these bridges

Results
Discussion
Conclusion