Abstract
Retro-mode is a novel technique capable of creating pseudo-3D images of the retina. However, its clinical utility remains unknown. This study aimed to evaluate the Nidek Mirante multimodal imaging platform for ocular assessment in patients with various retinal conditions. A total of 115 participants with central serous chorioretinopathy (CSR) and age-related macular degeneration (AMD) were included. Two experienced graders independently evaluated the images, and statistical analysis was performed to assess interclass correlation coefficients (ICC) between graders and modalities; Results: For CSR detection, retro-mode demonstrated exceptionally high ICC rates (ICC = 1; 100%), while color and autofluorescence (FAF) showed moderate coefficients (0.69 and 0.78, respectively). The detection of pigment epithelial detachment was high across all methods, with only retro-mode deviated right (DR) allowing detection in 69% of cases, while retro-mode DR and deviated left (DL) achieved 100% detection. FAF-green achieved a 95% detection rate. In detecting retinal atrophy, most modalities demonstrated high detection rates, with the lowest detection rates offered by retro-mode DL (ICC = 0.85) and DR (ICC = 0.89), while retro-mode ring aperture offered 0.97. Infra-red and fluorescein angiography imaging offered the highest detection rates among the tested modalities, with 97% and 100%, respectively. Retro-mode showed promise for comprehensive ocular evaluation and diagnosis, with certain imaging modalities demonstrating higher accuracy in detecting specific retinal features.