Abstract
A multiple failure event, a stuck-open pressurizer spray valve along with pressurizer pressure transmitter failure, which occurred on February 25, 1995, at Kori nuclear unit 2, is simulated using the best-estimate thermal-hydraulic computer code RETRAN03/MOD000. The simulation was performed to validate the predictive capabilities of RETRAN03 against plant data. The results would be useful in evaluation of the emergency operation procedures. The transient was simulated for 5000 s until the reactor coolant system pressure was stabilized and hot standby condition could be achieved. The simulation results and their corresponding plant data, especially for the evolutions of all the major thermal-hydraulic parameters, are compared and analyzed. Relatively good agreement between the plant data and the code prediction has been obtained; however, the simulation cannot duplicate the plant data for the low-flow condition that was encountered near the end of the transient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.