Abstract
Background A custom digital imagery method for real time identification and counting of pollen was qualitatively evaluated in the Environmental Exposure Unit (EEU). Methods Airborne grass pollen was collected in the EEU via a Rotorod ® impact sampler. The pollen grains on each sampling rod were counted using both traditional and headsup microscopy. The heads-up technique incorporated a microscope camera to create an on-screen image of the sampling rod. Firstly, unique images were created by manually advancing the stage, without duplicating previously captured pollen grains. Well-defined, sharp images were obtained by fine focus and zoom combinations to enhance certainty and recognition speed. Secondly, using a custom application, each pollen grain was identified and counted on-screen by “point and click” or “screen touch”, simultaneously counting and permanently anchoring opaque dots to the pollen grain locations. Counts were stored in real time on a central database. Results Increased clarity of the polle ng rains resulted in higher counting accuracy. Duplicate counting of pollen grains was eliminated by digitally labelling counted grains. Additional need for manual counting devices, commonly associated with mechanical and human errors, was eliminated. Error free counts can be obtained with increased speed, therefore, improving the overall efficiency of the process and the EEU system as a whole. Conclusions This validated heads-up counting technique will allow for an increased response time to changes in the EEU pollen levels. This advancement could also enhance pollen counting processes followed by others using direct microscopy pollen counting techniques.
Highlights
A post-hoc qualitative analysis of real time heads-up pollen counting versus traditional microscopy counting in the environmental exposure unit (EEU)
A custom digital imagery method for real time identification and counting of pollen was qualitatively evaluated in the Environmental Exposure Unit (EEU)
This validated heads-up counting technique will allow for an increased response time to changes in the EEU pollen levels
Summary
A post-hoc qualitative analysis of real time heads-up pollen counting versus traditional microscopy counting in the environmental exposure unit (EEU). Lisa M Steacy1*, Terry JB Walker, Barnaby Hobsbawn, Jenny Thiele, Anne K Ellis. From Canadian Society of Allergy and Clinical Immunology Annual Scientific Meeting 2014 Ottawa, ON, Canada. From Canadian Society of Allergy and Clinical Immunology Annual Scientific Meeting 2014 Ottawa, ON, Canada. 23-26 October 2014
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.